MIL-HDBK-1890(AT)
Clear annulus
0.15 R
Nugget size
D
Radius
R
Note:
1. No part should be acceptable when the number of welds having cracks, pores, or other instances of incomplete fusion with a linear dimension greater than 0.15D or that extend into the 0.15R clear annulus area, extends 6 percent of the total number of welds in the part.
FIGURE 1. Radiographic criteria for spot and seam welds in aluminum and aluminum alloys.